Configuring the System

32

TruPortal Software User Guide

Input Types

NO (Normally Open)

The sensor switch is normally open.

NC (Normally Closed)

The sensor switch is normally closed.

Unsupervised

The circuit is not wired with a continuity circuit to detect tampering.

Supervised

The circuit is wired with a continuity circuit to detect tampering.

Note:

For IPSDCs, refer to the IP-based Single Door Controller Quick Reference for
information about how to configure the switch settings based on input type selection.

Configure Readers

1.

Select System Administration > Devices.

2.

Expand the tree below the System Controller.

3.

Expand the tree below the Door Controller.

4.

Expand the tree below the Door.

5.

Select the Reader to configure.

6.

Select an Access Method.

Credential Only

Credential and PIN

PIN Only

PIN or Credential

7.

Select a Linked Camera if one is position to watch this door and reader.

8.

Click [Accept Changes].

9.

Repeat for other readers.

Reader Configuration Options

Credential Only

A person need only present a valid credential (ID badge) to gain access.

Credential and PIN

A person needs to present a valid credential and enter a Personal Identification Number (PIN) to
gain access. This prevents someone gaining access with a stolen or found credential. Some
facilities use Credential Only during the day and Credential and PIN after hours, when the
facility is empty.

PIN Only

A person need only enter a valid Personal Identification Number (PIN) to gain access.

PIN or Credential

A person needs to present either a valid credential or enter a Personal Identification Number
(PIN) to gain access.