First Time Configuration Wizard

AlterPath BladeManager Manual

4-5

Enter Date (format MM/DD/YYYY)

Enter Primary Ethernet IP Address (Static/None).

Enter Secondary Ethernet IP Address (Static/None)

Configure Ethernet Subinterfaces (Yes/No/List)

Configure Ethernet VLANs (Yes/No/List)

Enter Ethernet default gateway

Enter System’s Hostname (30 characters max)

Enter System’s Domain name (60 characters max)

Enter Primary nameserver’s IP address

Enter the NTP Server

Enter email (SMTP) server

Enter Authentication Method (local/radius/tacacs+/ldap/kerberos/nis/

active_directory)

Note: Depending on the Authentication Method that you select, the system

will prompt you for additional information. See “Setting the
Authentication Method” on page 4-8 for more information.

>> Resetting Configuration to Factory Settings

If you make a mistake during the First Time Configuration (or if you need to
make a change in the configuration), you can reset the configuration to its
factory default settings and start over. To reset the configuration, follow these
steps:

1. Log in to the management console as root.

2. Type in: defconf and press <Enter>.
3. Type in: reboot and press <Enter>.
Example:

BladeManager login: root

Password:

.
.
[root@BladeManager root]# defconf

WARNING: this will erase all of your current configuration and restore the
system's factory default configuration. This action is irreversible!