Configuring a redundant circuit, Conþguring a redundant circuit -2 – Cabletron Systems SPECTRUM SEHI100TX-22 User Manual

Page 46

Advertising
background image

Repeater Redundancy

4-2

Setting Network Circuit Redundancy

from the command line (stand-alone mode):

1.

From the appropriate directory, type:

spmarun r4red <IP address> <community name>

The main Repeater Redundancy window,

Figure 4-1

, will appear.

Figure 4-1. The Repeater Redundancy Window

Configuring a Redundant Circuit

To establish or edit a redundant circuit:

1.

In the Repeater Redundancy window, click mouse button 1 on the repeater
interface for which you would like to edit or establish a redundant circuit, then
click

. The Channel X Redundancy window,

Figure 4-2

, will appear.

NOTES

The spmarun script invoked Þrst in the above command temporarily sets the environment
variables SPMA needs to operate; be sure to use this command any time you launch an
application from the command line. The script is automatically invoked when you launch
the application from the icon menu or from within the Hub View.

If you wish to change any redundancy settings, be sure to use a community name with at
least Read/Write access. If you only wish to view
current settings, a community name
with Read access will be sufÞcient.

If there is a hostname mapped to your SEHI100TXÕs IP address, you can use <hostname>
in place of <IP address> to launch this application. Please note, however, that the
hostname is not
the same as the device name which can be assigned via Local
Management and/or SPMA; you cannot use the device name in place of the IP address.