Crestron DIN-AP2

DIN Rail Control Processor

marked Ethernet however, communications must be established in
order to see this information in the “System Info” window.

• Display the DIN-AP2’s “System Info” window (click the

icon); communications are confirmed when the device information
is displayed.

TCP/IP

Ethernet Communication

ETHERNET

PC RUNNING

CRESTRON

TOOLBOX

DIN-AP2

• Establish USB communication between DIN-AP2 and PC.
• Enter the IP address, IP mask, and default router of the DIN-AP2

via the Crestron Toolbox (Functions | Ethernet Addressing);
otherwise enable DHCP.

• Confirm Ethernet connections between DIN-AP2 and PC. If

connecting through a hub or router, use CAT5 straight through
cables with 8-pin RJ-45 connectors. Alternatively, use a CAT5
crossover cable to connect the two LAN ports directly without
using a hub or router.

• Use the Address Book in Crestron Toolbox to create an entry for

the DIN-AP2 with the DIN-AP2’s TCP/IP communication
parameters.

• Display the “System Info” window (click the

icon) and select

the DIN-AP2 entry.

• Use Crestron Toolbox to create the DIN-AP2 IP table.

⇒ Select Functions | IP Table Setup.
⇒ Either add, modify, or delete entries in the IP table. The

DIN-AP2 can have only one IP table entry.

⇒ A defined IP table can be saved to a file or sent to the

device.

• When using the DIN-AP2 as a “slave”, edit the “master” control

system’s IP table to include an entry for the DIN-AP2. The entry
should list the DIN-AP2’s IP ID (specified on the DIN-AP2’s IP
table) and the internal gateway IP address 127.0.0.1.

Operations & Installation Guide – DOC. 6662A

DIN Rail Control Processor: DIN-AP2

23