DIN Rail Control Processor

Crestron DIN-AP2

6. Once the DIN-AP2 is in Monitor mode, connect to the PC using a

USB cable.

NOTE: If at any point in the above sequence, one of the timer
periods expires without the SW-R button being pressed, the unit
will boot normally, first running the firmware, then loading the
application.

NOTE: If your PC does not have the USB driver installed, after
connecting the DIN-AP2 to the PC using the USB cable, you will
see a dialog box on your PC screen asking you to install the USB
driver. For instructions on how to install the USB driver, refer to
the Crestron Toolbox help file.

7. Open Toolbox and start the Text Console (click the

icon).

Then, click on the Address Book icon in the lower left corner of
the window to open the “Address Book” window.

8. In the “Address Book” window, click the Add Entry button and

give the new entry a name (e.g. “System Monitor”).

9. Click the arrow next to the Device Type drop down list. A

“Warning” window will open to inform you that this is an
advanced feature. Click OK, then select “2-Series Control System
Monitor” from the drop down list. Make sure to choose USB as
the Connection Type, then click OK. The following text will
appear in the bottom right corner of the “Text Console” window:

usb;device 2SeriesCtrlSystemMonitor

The following text will appear in Toolbox:

MONITOR>

10. At the Toolbox prompt, type erase and press Enter. The following

text will appear in Toolbox:

Erasing

->25%->50%->75%->100%

Done

11. Click the

icon and select Firmware… to open the

“Firmware” window, then click Browse.

28

DIN Rail Control Processor: DIN-AP2

Operations & Installation Guide – DOC. 6662A