Ldvt series direct vent gas fireplace, Hearth, Final finishing framing and finishing – Vermont Casting 43LDVT User Manual

Page 6: Gas inlet and manifold pressures, Gas specifications

Advertising
background image

6

LDVT Series Direct Vent Gas Fireplace

10007852

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305mm) or more from the
front of the fireplace.
Cold climate installation recommendation:

When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.

Hearth

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.

Final Finishing

Framing and Finishing

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Inlet and Manifold Pressures

Check fireplace to make sure it is levelled
and properly positioned.

To mount the appliance:
1. Choose the location.
2. This unit comes with four (4) flanges pre-mounted

on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange “A” is for
1/2” drywall while flange “B” is for 5/8” drywall.

3. Bend the desired flanges out 90° on both sides of

the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.

A

B

FP1546

LDVT nailing flanges

1/05

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

Flange Location for Desired Drywall Depth

FP1546

Fig . 4 Nailing flanges.

*Using conversion kit

Max.

Min.

Air

Gas

Input

Input

Shutter

Model

Fuel Control BTU/h BTU/h

Adj.

33LDVTRN

Nat Millivolt 16,000 11,200

3/16”

Open

33LDVTRP

Prop Millivolt 16,000 12,000 Fully Open

33LDVTEN

Nat

24V

16,000 11,200

3/16”

Hi/Lo

Open

33LDVTEP Prop*

24V

16,000 12,000 Fully Open

Hi/Lo

36LDVTRN

Nat Millivolt 19,500 13,650

Top &

Bottom

Hole Half

Closed

36LDVTRP Prop Millivolt 19,500 14,625 Fully Open
36LDVTEN

Nat

24V

19,500 13,650

Top &

Hi/Lo

Bottom

Hole Half

Closed

36LDVTEP Prop*

24V

19,500 14,625 Fully Open

Hi/Lo

39LDVTRN

Nat Millivolt 23,000 16,100

Top &

Bottom

Hole Half

Closed

39LDVTRP Prop* Millivolt 22,500 16,875 Fully Open
39LDVTEN

Nat

24V

23,000 16,100

Top &

Hi/Lo

Bottom

Hole Half

Closed

39LDVTEP Prop*

24V

22,500 16,875 Fully Open

43LDVTRN

Nat Millivolt 26,000 18,200

Top &

Bottom

Hole Half

Closed

43LDVTRP Prop* Millivolt 24,000 18,000 Fully Open
43LDVTEN

Nat

24V

26,000 18,200

Top &

Hi/Lo

Bottom

Hole Half

Closed

43LDVTEP Prop*

24V

24,000 18,000 Fully Open

Hi/Lo

Gas Specifications

Advertising