Ldvt series direct vent gas fireplace, Electronic gas control valve eb-1 electrical box – Vermont Casting 43LDVT User Manual

Page 8

Advertising
background image

8

LDVT Series Direct Vent Gas Fireplace

10007852

This appliance may be fitted with a Synetek ignition
module.
Installation of the remote on/off switch or wall ther-
mostat on electronic ignition units.
1. Thread the wiring through the holes on the side

panels of the appliance. Take care not to cut the wire
or insulation on metal edges. Route the wire to a
conveniently located receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the white wire from the wall switch or wall

thermostat to the white wire terminal from the elec-
tronic module. Connect the black wire from the wall
switch or the red wire from the wall thermostat, to
the red wire terminal from the electronic module.

Electronic Gas Control Valve

EB-1 Electrical Box

The fireplace, when installed, must be elec-
trically connected and grounded in accord-
ance with local codes or, in the absence
of local codes, with the current CSA C22.1
Canadian Electrical Code.

For USA installations follow local codes
and the national electrical code ANSI/
NFPA No. 70.

It is strongly suggested that the wiring of
the EB-1 Electrical Junction Box be carried
out by a licensed electrician.

Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.

The EB-1 Electrical junction box has been fitted stand-

ard on this model to allow for the easy connection of an

optional fan kit.
To connect the EB-1 box to the house electrical supply

follow the steps below.
1. Unscrew retaining screw from EB-1 base plate (Fig.

8) and remove the EB-1 assembly from the appli-

ance.

2. Remove the front cover of the EB box.
3. Remove the plug socket assembly from the EB-1

box.

4. Feed the supply line in through the EB-1 opening in

the side of the appliance and then through the back

of the EB-1 assembly. (Fig. 8)

5. Connect the black wire of the power supply line to

the brass screw (polarized) of the socket assembly.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable

with the clamp on the outside of the EB-1 base

plate and refit the EB-1 assembly to the unit with the

screw removed in step 1.

FP580

INSTA VENT FREE

EB1 JUNCTION BOX

11/18/97

OUTSIDE

������������

INSIDE

BACK OF UNIT

Electrical Box

Retaining Screw

FP580

Fig. 8 EB-1 receptacle.

Advertising