Revision 0.03

17

Activating the Special Operations Mode and Default Settings

Blue Heat/Net Sync includes a push button on the rear of the unit beside the DC power
connector. This push button can be used to perform special operations such as resetting the unit
to its default settings or forcing port scanning in situations where the SCM is not accessible.

Using the Reset Button to Activate the Special Operations Mode

To activate the Special Operations Mode, hold the reset button while the unit is powering up.
Hold the button until all the port LEDs blink rapidly and then release the reset button. The port
LEDs will continue to flash rapidly after the reset button is released to indicate the Special
Operations Mode is active.

Selecting a Special Operation

Once the Special Operations Mode has been activated, four operation options are available:

1.

Abandon the Special Operations Mode

To abandon the Special Operations Mode without selecting a special operation, press
and hold the reset button for at least four seconds. While the button is pressed, the
rapid flashing of the port LEDs will stop. After four seconds, the rapid flashing will
resume and the reset button can be released. After the release of the reset button, the
port LEDs will turn off, indicating that the Special Operations Mode has terminated.

2.

Cancel a Special Operation

If you need to cancel a special operation after it has been selected, repeatedly press the
reset button until all the port LEDs begin to flash rapidly. Then abandon the Special
Operations Mode by pressing the reset button for four seconds, as explained above.

3.

Select a Special Operation

Operations are selected by repeated short presses of the reset button. Each time the
reset button is pressed it is counted and represented on the port LEDs as a binary
number with the port 1 LED as the least significant bit

(see Table 1)

. Choose the

operation which you want to perform. If you miss the selection that you want, keep
pressing the button. The count starts over again once it reaches 7 (1111 binary).

4.

Activate a Special Operation

To activate a selection, press and hold the reset button for at least four seconds. During
this time the rapid flashing of the port LEDs will stop. Once the rapid flashing resumes
you can release the reset button. The port LEDs will turn off indicating that the Special
Operations Mode has been activated.

Advertising