2 proper use of the lifting device, Proper use of the lifting device – KERN & SOHN VFS 2T1 User Manual

Page 12

Advertising
background image

VFS-BA-e-1111

12

5.2 Proper use of the lifting device



Ö Lower the loading fork




Ö Move the load




Ö Lift the loading fork

5.3 Installation site, location of use of the weighing system

The weighing system is designed to achieve reliable weighing results under normal
conditions of use.
You will work accurately and fast, if you select the right location for your weighing
system.
Therefore, observe the following for the installation site:

• The load must be lifted clear of the display unit’s case and other pallets.

Incorrect lifting of a load

Correct lifting of a load


• The accuracy of the weighing system is falling by approximately 0.1 % per degree

if there is a slant of more than 2°. Holes and unevenness, too, have this effect. A
smooth floor is ideal.

• Optimum accuracy in weighing results is achieved if the load centre is between

the forks. The forks are easily bent and twisted when the load is off-centre. This
may result in diminished accuracy.
In verifiable models off-centre loads, or slants affecting accuracy, activate the
inclination switch which in turn disconnects the display.

Advertising