2 weighing, 1 gross - net weighing, 2 net weighing – KERN & SOHN VFS 2T1 User Manual

Page 23: 3 weighing units switch-over, Weighing, Gross - net weighing, Net weighing, Weighing units switch-over

Advertising
background image

7.2 Weighing
Ö Press downwards the hand lever of the lifting device, the weighing system is

lowered.

Ö Switch-on by

, after a concluded self-test the system changes to zero display

0.0

Ö If „0.0“ is not displayed, press

Ö Place the loading fork under the pallet in a way that the pallet is in the centre of the

loading fork.

Ö Move upwards the loading fork with help of the lifting device until the load has

completely detached from the floor
If the stability display „STABLE“ lights up, the gross weight will be displayed.


Printout example (see chap. 8 Printer):
Date 2011/06/09 Date

Time 17:34:27 Time

18.30

kg Weight

7.2.1 Gross - net weighing

After the load was lifted, e.g. on a pallet, the display shows the gross value of the
weighed weight.

7.2.2 Net weighing

This function may only be carried out, after the system having been
tared. “NET“ will be displayed

Use the button

to switch over between the display of the net weight and the

display of the gross weight.

7.3 Weighing units switch-over

Press the UNIT button to set the different weighing units.
These must be activated in menu (chap. 9.2) before.