Carry out adjustment by entering the adjustment weight
Switch off weighing system
Press
for 30 sec., PAR is displayed
Press
until CAL is displayed
Press
, ZERO is displayed flashing, because the
reference height is not reached yet
Place a pallet and adjust the reference height, when the
reference height is reached, the display stops flashing and
only the righthand bar above in the display continues to be
displayed.
Press
for approx. 3 sec., the count down runs off
automatically.
.1000 is displayed.
Press 2 x
, 0 is displayed
Press
shortly, the display for entering the
adjustment weight is displayed, the right digit flashes.
Use both keys to enter the desired adjustment weight:
Use
to alter cipher, use
to change the digit
(example)
INFO: when entering 1500 kg = enter 15000 (example). With the other values
proceed in the same way: the last zero will not be considered:
14