background image

B. System

Specifications


ENVIRONMENTAL

Temperature

-10F

to

+12OF

Humidity 90%

RH,

Non-condensing

Surge

2500

V,

Per

ANSI

C37-90A-1974, common and

differential mode

EMI/RFI

per

FCC

part

15C


ELECTRICAL

Power requirements

120 VAC, 50/60 Hz, 7 watts

Fault sensing current

Less then 10 mA per channel

Battery

Backup 4

hours

typical

Power outage detection time

1-99 seconds


PHYSICAL

Dimensions

11 5/8 x 9 7/16 x 4 inches

Weight

10

lbs.

Mounting method

Flange mount, 4 points

Enclosure

NEMA

12

std.,

others

optional


TELEPHONE SYSTEM

FCC registered for direct interconnect

FCC Registration Number:

D4J6M6-13598-AL-E


Dialing capacity

8 numbers, 16 digits each,

maximum

Dialing format

Loop disconnect, 10 pps

nominal; or tone,

100ms/100ms;

user

selectable

Answer delay

Programmable, 1 to 99 rings

Acknowledged intercall delay

Programmable, 1 to 99 hours

Unacknowledged intercall delay

One Minute

Surge and environmental protection

Per FCC part 68


OPERATIONAL

Fault detection method

Normally open or closed,

selectable

Fault integration time constant

One to 99 seconds

Station

identification

Name

or number, user selectable

user programmable messages

Message repetitions

One to 99, user programmable

Data retention

Nonvolatile EEPROM

Programming

Local keyboard entry

20

Advertising