Inter nal User Adjustments

Inside the unit you will find the 115/230 voltage switch. Normally this
will be set to the proper voltage of the country of purchase. If you
need to switch the voltage, it can be found between the power plug
socket and the toroidal transformer. The voltage value is printed next
to the switch.

*For Japanese models only: 115V = 100V, 230V = 230V

There are also jumpers which allow bypass of the capacitors in the
analog input signal path. Connecting jumpers will extend the low-
frequency response to 0 Hz. It will also allow DC to pass. Bypass the
capacitors only if you are sure that there is no DC in your signal, as
DC can be harmful. The jumpers are located behind the output
XLR's.

Internal -6db Gain
Jumpers
These 4 jumpers allow
the user to lower the
output level of the DAC
by -6 db without
affecting sound quality.
All 4 jumpers must be
engaged to ensure
proper operation and
should only be used
when the DAC is
clearly overloading the
following

amplifier

stage in the chain.

www.mytekdigital.com