PCI Interrupt, Clock and ID Selection

The following PCI signals, (INTA#, INTB# INTC# INTD#), (CLK0, CLK1,
CLK2, CLK3), (IDSEL0, IDSEL1, IDSEL2, IDSEL3), are selected by using the
Rotary Switch on the CANpro/104-Plus Opto board (RSW1). Selections need to
match the stack location of the CANpro/104-Plus Opto in your PC/104-Plus
stack. See

Table 1

below for more details.



Rotary Switch Location

Table 1: Rotary Selection

Stack Location

Rotary Setting

PCI INT#

PCI CLK

PCI IDSEL

0 or 4

INTA#

CLK0

IDSEL0

1 or 5

INTB#

CLK1

IDSEL1

2 or 6

INTC#

CLK2

IDSEL2

3 or 7

INTD#

CLK3

IDSEL3

Please visit

http://www.pc104.org/pc104_plus_specs.php

to request the full PC/104-Plus specification for

more details on signals.