On-Board Jumper Configuration

Figure 3: CAN Ports and Jumper Locations

120 Ohm Termination Jumpers

Jumpers J1 and J4 will enable a 120 Ohm termination resistor across the CAN-H and CAN-L lines.
Termination is always recommended for improved signal integrity, especially for long transmission lines.
Termination requirements should be evaluated on a case by case basis. Typically both ends of a CAN bus are
terminated, but termination is not enabled on cards that sit in the middle of the bus. See

Figure 4

and

Figure 5

for examples that indicate when to use this jumper selection.

Figure 4: Example – CANpro/104-Plus Opto at the end of a CAN bus