On-board jumper configuration, Figure 3: can ports and jumper locations, 120 ohm termination jumpers – Connect Tech CANpro/104-Plus User Manual
Page 9
CANpro/104-Plus Opto User Manual
9
www.connecttech.com
CTIM-00052 Revision 0.00 4/23/2009
800-426-8979 | 519-836-1291
On-Board Jumper Configuration
Figure 3: CAN Ports and Jumper Locations
120 Ohm Termination Jumpers
Jumpers J1 and J4 will enable a 120 Ohm termination resistor across the CAN-H and CAN-L lines.
Termination is always recommended for improved signal integrity, especially for long transmission lines.
Termination requirements should be evaluated on a case by case basis. Typically both ends of a CAN bus are
terminated, but termination is not enabled on cards that sit in the middle of the bus. See
for examples that indicate when to use this jumper selection.
Figure 4: Example – CANpro/104-Plus Opto at the end of a CAN bus
NOTE:
The 120 Ohm termination jumper must be installed in this
situation.