Electrical Requirements

Supply

Changing
the fuse

Moulded plug

Changing
the plug

Rewirable plug

Changing the
mains cable

WARNING: This appliance must be earthed!

REFER TO THE RATING PLATE FOR VOLTAGE AND CURRENT
REQUIREMENTS. (see diagram for location.)
The flexible mains lead is supplied fitted with a BS1363 plug and
with a 13 amp BS1362 fuse.
The plug should be connected to the mains supply via a suitable
switched socket which is accessible after installing your dryer.

If it is necessary to fit a replacement fuse, it must be a 13 amp
ASTA approved to BS1362 type.

If a replacement fuse holder/cover is required, it must be of the
same colour coding or wording as shown on the base of the plug.
Replacements are available from your Spares stockist.

The wires in the mains lead are coloured in accordance with the
following:
GREEN/YELLOW - EARTH
BLUE

- NEUTRAL

BROWN -

LIVE

If a replacement plug is to be fitted, the appropriate wire must be
connected to the correct terminal, the following gives some
examples.
Connect:
Green/Yellow to terminal marked Earth or Green or
Blue to terminal marked Neutral or N or Black
Brown to terminal marked Live or L or Red.
if the plug being replaced is a non-rewirable type then the cut-off
plug must be disposed of safely. DO NOT leave where it can be
inserted into a socket and create a shock hazard.

Should the mains lead ever require replacing at any time please
contact your nearest Service Centre. A charge will be made for the
replacement of the mains lead or if you require a longer lead.
The mains lead must only be replaced by a specially prepared
cable obtainable from your Spares Stockist and fitted by a
qualified electrician.

WARNING: The plug must not be used without a fuse cover.

NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE CONSULT A
QUALIFIED ELECTRICIAN.

GREEN &

YELLOW TO

EARTH

13 AMP

FUSE

BROWN
TO LIVE

CORD

CLAMP

BLUE TO

NEUTRAL