Continental BCDV42N User Manual

Page 22

Advertising
background image

22

W415-0385 / A / 10.02.03

ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-
FIED INSTALLER
and must be connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 C

ANADIAN

ELECTRICAL

CODE

in

Canada or the ANSI/NFPA 70

NATIONAL

ELECTRICAL

CODE

in the

United States.

To safely install the fan, turn off the electricity first.

Use of the fan increases the output of heat.

Unplug the power cord from the receptacle. Connect all
wires as shown.

Attach and secure the sensor assembly bracket to the se-
curing stud located next to the receptacle/junction box at
the bottom left of the unit using the lock washer and wing
nut. Ensure that the thermodisc touches the firebox wall.

Plug the power cord back into the receptacle.

When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot ob-
jects.

This optional kit is meant to be used only in conjunction
with the GD65 Fan Kit, shown above, which may be or-
dered from your Wolf Steel / Continental dealer.

With the thermostatic sensor option, the fan, when turned
on, becomes thermally activated, and will automatically run
approximately 15-30 minutes after the fireplace has been
lit and for approximately 30-45 minutes after the fireplace
has been turned off.

If the fireplace was not previously equipped with a fan:
route a grounded 2-wire, 60hz power cable to the junction
box. At this point, it must be strain relieved and insulated.

The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is con-
tained, preventing it from making contact with moving or
hot objects.

To ease installation of the fan, re-
move the hinge screen and valve
control door (lower louvres) from
the base of the fireplace.

Position the vibration reducing pad
into the clip and onto the threaded
stud at the other end, piercing a hole into the pad. The fan
assembly must be able to be positioned entirely onto the
pad.

Slide the fan assembly past the controls and into the clip.
Secure using the lock washer and nut provided.

Plug the harness cord into the receptacle.

RECEPTACLE /

JUNCTION BOX

OPTIONAL THERMOSTATIC

SENSOR

SLOTS

OPEN ENDED

VARIABLE SPEED/

BRACKET

PIEZO IGNITOR

JUNCTION BOX

THERMODISC

SENSOR ASSEMBLY

BRACKET

RECEPTACLE /

FIGURE 49

FIGURE 48

FIGURE 50

FIGURE 51

OPTIONAL FAN INSTALLATION

GD36 THERMOSTATIC SENSOR CONTROL

Advertising
This manual is related to the following products: