Pilot will not light.

- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.

No spark at pilot burner

- fill the tank.

Out of propane gas
Spark gap is incorrect

- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from
the electrode tip and the pilot burner. To ensure proper electrode
location, tighten securing nut (finger tight plus 1/4 turn).

No gas at the pilot burner

- check that the manual valve is turned on.
- check the pilot orifice for blockage.
- replace the valve.
- call the gas distributor.

Main burner goes
out; pilot stays on.

Pilot flame is not large
enough or not engulfing the
thermopile

- turn up pilot flame.

- replace pilot assembly.

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

- replace thermopile / valve.

Remote wall switch wire is
too long; too much resist-
ance in the system.

- shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

- replace.

5" flexible vent has become
disconnected from fireplace.

Pilot goes out when
the gas knob is re-
leased.

The gas valve has
an interlock device
which will not allow
the pilot burner to
be lit until the ther-
mocouple has
cooled. Allow ap-
proximately 60
seconds for the
thermocouple to
cool.

System is not correctly
purged.

- purge the gas line with the glass door removed.

Out of propane gas.

- fill the tank.

Pilot flame is not large
enough

- turn up the pilot flame.

- gently twist the pilot head to improve the flame pattern around the
thermocouple.

Pilot flame is not engulfing
the thermocouple.

Thermocouple shorting /
faulty.

- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.

Faulty valve.

- replace.

Pilot burning; no
gas to main
burner; gas knob
is on 'HI'; wall
switch / thermostat
is on.

Themostat or switch is de-
fective.

- connect a jumper wire across the wall switch terminals; if main
burner lights, replace switch / thermostat.

Main burner orifice is plugged.

- remove stoppage in orifice.

Faulty valve.

- replace.

Wall switch wiring is defec-
tive.

- disconnect the switch wires & connect a jumper wire across termi-
nals 1 & 3; if the main burner lights, check the wires for defects and
/ or replace wires.

Main burner goes
out; pilot goes out.

Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"

Vent is blocked

Vent is re-circulating

- check for vent blockage.

- check joint seals and installation.

- re-attach to fireplace.