Continental BCDV42N User Manual

Page 6

Advertising
background image

6

W415-0385 / A / 10.02.03

*

Recommended to prevent condensation on windows and thermal breakage

**

Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of
18". It is recommended to maximize the distance to vinyl clad soffits.

***

The periscope GD-401 requires a minimum 18 inches clearance from an inside corner.

****

This is a recommended distance. For additional requirements check local codes.

Three feet above if within 10 feet horizontally.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings.

††

Permitted only if the veranda, porch or deck is fully open on a minimum of two sides beneath the floor.

†*

Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.

A
B
C

D
E

F

G

H

I

J

K

L

M
N
O

12 INCHES

9 INCHES

12 INCHES*

32 INCHES**

32 INCHES**

0 INCHES

0 INCHES***

2 INCHES***

3 FEET****

3 FEET****

9 INCHES

3 FEET†

7 FEET****

32 INCHES****

16 INCHES

2 FEET†*

Clearance above grade, veranda porch, deck or balcony.

Clearance to windows or doors that open.

Clearance to permanently closed windows.

Vertical clearance to ventilated soffit located above the terminal within
a horizontal distance of 2 feet from the centerline of the terminal.

Clearance to unventilated soffit.

Clearance to an outside corner wall.

Clearance to an inside non-combustible corner wall or protruding
non-combustible obstructions (chimney, etc.).

Clearance to an inside combustible corner wall or protruding com-
bustible obstructions ( vent chase, etc.).

Clearance to each side of the centerline extended above the meter
/ regulator assembly to a maximum vertical distance of 15ft.

Clearance to a service regulator vent outlet.

Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.

Clearance to a mechanical air supply inlet.

Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301.

Clearance under a veranda, porch, deck or balcony.

**

Clearance above the roof.

Clearance from an adjacent wall including neighbouring buildings.

CANADIAN

U.S.A.

12 INCHES

12 INCHES

12 INCHES*

32 INCHES**

32 INCHES**

0 INCHES

0 INCHES***

2 INCHES***

3 FEET

3 FEET

12 INCHES

6 FEET

7 FEET‡

32 INCHES††

16 INCHES

2 FEET†*

INSTALLATIONS

AIR TERMINAL INSTALLATIONS

FIGURE 2