Adjust the pilot screw to provide properly sized flame. Turn
in a clockwise direction to reduce the gas flow.

Air shutters have been factory set open according to the
chart below:

These settings are for the maximum horizontal vent run.-
Adjustment may be required depending on fuel type, vent
configuration and altitude.

Closing the air shutter will cause a more yellow flame, but
can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner
ports. The flame may not appear yellow immediately; allow
15 to 30 minutes for the final flame colour to be estab-
lished.

Air shutter adjustment must only be done by a

qualified installer!

To access the air shutter, remove the two screws that se-
cure the cover to the air housing, taking care not to dam-
age the gasket.

FIGURE 53

AIR SHUTTER

NG

1/4"

LP

7/16"

FIGURE 54

FIGURE 52

COVER

VENTURI

FIGURE 55

PILOT SCREW

LO

OT

PIL

IH

PL

O

O

FF

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

VENTURI ADJUSTMENT