Step

4. Secure in place by tightening Truss Hook wing bolts (Figure 2-6). Ensure that luminaire is fully supported.

Step

5. Feed safety cable through base and secure around pipe as shown in Figure 2-6.

Step

6. Connect power and data cables according to

"Connecting Power and Data"

on page 20.

Figure 2-6: Standard Hanging Configuration and Dimensions

28.6"

(726 mm)

(736 mm)

29"

16.75"

(425 mm)

(279 mm)

11.0"

34.8"

(884 mm)

(978 mm)

38.5"

(147 mm)

5.78"

3.88"

(99 mm)

28.6"

(726 mm)

(610 mm)

24.0"

(483 mm)

19.0"

(486 mm)

19.15"

12.5"

(318 mm)

31.0"

(787 mm)

(696 mm)

27.4"

At least one (1) Safety Cable MUST be
used for all hanging installations and
may be required by local codes.

Safety cable and input pigtail cable
must be dressed to avoid interference
with luminaire motion.

NOTE

: Mega-Claw Truss Hook is designed to

be used only with 2.0" OD round tubing.

POSITIONING

:

Can be mounted in any orientation.

SPACING

:

Hangs on 29 inch (736 mm) centers

WEIGHT

:

88 lbs (39.9 kg) without hooks