Other Errors

Error Code

Explanation

Solution

Ballast Errors: Parity, Overrun,
Bad Header, Msg Too Long

Various ballast errors

Check ballast comm cable/connections

Ballast Heat Sink Over Temp

Ballast too hot

Check fans

Ballast Lamp EOL H/L Voltage
Limit

Lamp life limit exceeded

Check lamp

Ballast Line Voltage Low

Wrong voltage to strike

Check power connection

Ballast Short Detected

Short circuit on ballast output

Check wiring

Ballast Timeout: Lamp Strike

Lamp failed to strike

Check igniter, lamp

CAN Comm Error

Stopped receiving CAN messages from
motion processor

Check CAN cables/connections, motor
control board

Crossload Timeout

Crossload execution took too long due to
error

Remove any incoming DMX, retry

Current Foldback Error

Short in the drive circuitry or an electrical
problem with motor

Check motor, motor cabling

Data Not Crossload Format

Data in memory is not proper format for
crossload

Load software via computer

DMX Busy: Cancel Crossload

Cannot execute crossload with traffic on
DMX line

Remove incoming DMX control for cross
load

DMX: UART transmit error

Transmit buffer busy when trying to send

Remove any incoming DMX, retry

Drive Fault

Fault detected in a drive mechanism

Check mechanism

Fan Error

Fan not running properly

Check fan, fan cabling

Gobo Out of Zero Range

When zeroing gobo wheels, the wheel is
too far away from zero to set the position

Move wheel closer to home position
before zero command

Lamp EOL Voltage Limit

Lamp at end of life

Check and replace lamp

Lamp Off

Fan Error: Cannot strike lamp while any
fan is in error state

Check fan, fan cabling

Lamp Off: Over Temperature

Head temperature too high

Check fans

Lamp Over Threshold

Lamp hours above recommended
maximum

Change lamp

No Current Cal Values

Channel had trouble retrieving the
calibration values from the PIC micro

Check CAN cables/connections, motor
control board

PMD Motion Error

Mechanism's actual position is too far
from its commanded position

Check mechanism motion

Temp Over Threshold

Temperature too high

Check fans/filters