Status screen, Information screen, Test screen – PRG Best Boy Wash User Manual User Manual

Page 43

Advertising
background image

BEST BOY

®

WASH LUMINAIRE USER MANUAL

35

Status Screen

+

Mechanisms - displays mechanism status. Mechanism names will
be shown in yellow while calibrating, then change to green if okay or
red if an error exists. Locked mechanisms will be shown in white.
Press to bring up Test Screen.

+

Log - displays system status log. Use touchscreen arrows to scroll
up or down. Press the log panel itself to scroll all the way back to
the most recent log entries. Press CLR to bring up Clear Log Yes/No
options.

The log entries are stored in persistent memory and are retained even if
the luminaire is powered off.

Press (X) to return to

Home Screen

.

Information Screen

+

Fixture Hours - displays total number of hours that the fixture has
been operated.

+

Run Time - displays current run time in

hours:minutes

format.

+

Software Version - displays current version of operating software
and boot.

+

Firmware Version - displays current firmware version of Head and
Yoke controllers.

+

Crossload - allows the luminaire to send its software version out
over the DMX512 and Ethernet lines to other connected luminaires
in the daisy-chain. (See

"Software Crossload"

on page 56 for more

explanation of this function.)

Press (X) to return to

Home Screen

.

Test Screen

+

Recalibrate - press to bring up Recalibration Screen. (During
recalibration, intensity goes out until all mechanism calibrations are
complete and back in position, then fades in.)

+

Recal All - press to bring up Recalibrate All Yes/No options.

+

Mech Test - press to bring up Mechanical Tests Screen. (See

"Mechanical Tests"

on page 53 for more explanation.)

+

Group Test - press to bring up Group Tests screen, which allows
multiple luminaires to be run through a configurable test sequence
when chained together via DMX512 or Ethernet. (See

"Group Tests"

on page 54 for more explanation.)

+

Disable - press to bring up Disable Screen, which allows specific mechanisms to be disabled during testing.

+

Clean Lenses - press to bring up Cleaning Lenses screen. This feature will position lenses so that all surfaces
may be cleaned with a cloth. (Note that pressing the buttons does not actually clean the lenses.)