Diagnostics menu, Way wireless rf touchpanel crestron st-1700c – Crestron electronic ST-1700C User Manual

Page 14

Advertising
background image

1-Way Wireless RF Touchpanel

Crestron ST-1700C

Power Management Timeout Settings

POWER MANAGEMENT TIMEOUT
SETTINGS

The Power Management feature is intended to conserve energy and to extend the
service life of the battery. From the STARTUP screen, press the Power
Management
button to display the POWER MANAGEMENT TIMEOUT
SETTINGS Screen. Use the STANDBY and POWER DOWN UP and DOWN
buttons to set the respective timeouts from 0 through 120 minutes, where 0 disables
the timeout. The time settings are in single-minute increments from 0 to ten minutes,
and in 10-minute increments from 10 minutes through 120 minutes.

Use the Standby Now and Power Down Now buttons to immediately enter the
respective mode.

STANDBY timeout turns the display and backlight off when the touchpanel is
inactive for the specified time. When the touchpanel is reactivated, the last screen to
be displayed reappears. The specified time is displayed in minutes. The default
STANDBY timeout is 10 minutes.

POWER DOWN timeout turns off all power when the touchpanel is inactive for the
specified time. When the touchpanel is activated, either the first page of the project
appears or the last screen to be displayed reappears, depending on the setting of the
Power Up On Last Page option on the Startup Preference screen. The specified time is
displayed in minutes. The default POWER DOWN timeout is 30 minutes.

NOTE: Power Down Timeout should be set low to maximize battery life. However,
Power Down Timeout should be set greater than Standby Timeout. Otherwise, the
Standby Timeout is meaningless.

NOTE: When the panel is powered down, it will take about 1.5 seconds to power up
and respond to a button press. There is no such delay from Standby mode

NOTE: If the external AC power pack is attached to the touchpanel and plugged into
an active AC receptacle, or if the touchpanel is resting in the docking station (ST-DSN)
and plugged into an active AC receptacle, the panel does not power down when the
power down timeout is achieved. Recall that the purpose of this timeout is to maximize
battery life. Standby timeout still functions.

Press Return to save the settings and return to the SETUP MENU.

Diagnostics Menu

DIAGNOSTICS MENU

The Diagnostics button from the MAIN MENU should only be used under
supervision from a Crestron customer service representative during telephone
support. Many options available from the DIAGNOSTICS MENU, shown to the left,
are numeric in nature and their interpretation is beyond the scope of this manual.

10

1-Way Wireless RF Touchpanel: ST-1700C

Operations Guide – DOC. 6050