Table 5.3. Oxygen alarms in NITROX mode

Alarm reason

Alarm type

The OLF bar graph reaches 80%. The segments ex-
ceeding the 80% limit start to blink.

Three double beeps and the
backlight for five (5) seconds

The OLF bar graph reaches 100%. The OLF value
will blink. The blinking of the segments exceeding 80%
will stop, when the OLF is not loading anymore. At
that point the PO2 is less than 0.5 bar.

Set oxygen partial pressure limit is exceeded. The al-
ternative display is replaced with a current blinking
PO

2

value. You should immediately ascend above the

PO

2

depth limit.

Continuous beeps for three (3)
minutes and activated back-
light for five (5) seconds

NOTE

When the backlight is turned OFF, it does not illuminate when an
alarm is activated.

WARNING

WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE
MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY
TAKE ACTION TO REDUCE OXYGEN EXPOSURE. Failure to
take action to reduce oxygen exposure after the warning is given
can rapidly increase the risk of oxygen toxicity, injury, or death.