Min prs, Application setup mode – TeeJet 844-R Speed Compensated Application Control User Manual

Page 24

Advertising
background image

24

98-05047

R0

M

INIMUM

P

RESSURE

S

ETTING


Set the minimum pressure that the controller will be allowed to regulate to.
Sometimes when the applicator speed slows down, the control system will
regulate the pressure so low that it falls below the pressure required to open the
check valves on the individual nozzle bodies.

This is typically set to the minimum
recommended pressure nozzle body
check valves.

Use the

+

or keys to adjust

the minimum pressure.

Press the

P

RO

key to advance to

the next step.


I.e. If this step is set to 15 psi the
console, in automatic mode, will not
regulate pressure below 15 psi.


Application Setup Mode


To access the Application Preset Setup Mode, press the

P

RO

key two times.

(Master switch must be OFF)

T

ARGET

A

PPLICATION

R

ATE


After entering the Application Setup Mode, the Target symbol should be flashing.
If it is not, press the

P

RO

key 3 or 4 times until the Target symbol is flashing,

indicating that the target rate is ready to be changed.

Press the

+

key to increase the

target rate or key to decrease
the target rate.

Press the

P

RO

key to accept the

value and advance to the next
step.





10

Min PrS

PSI

GPA

2.0

15

6.0

0.40

MPH

PSI

Advertising