Daily flow meter maintenance – TeeJet 844-R Speed Compensated Application Control User Manual

Page 26

Advertising
background image

26

98-05047

R0

Pressing the

P

RO

key again will take you back to the pressure calculation step.



Known Pressure Calculation


Adjust the pressure value to the desired operating pressure and the speed value will
automatically change to reflect the approximate speed required to achieve the
programmed target rate at the pressure selected. This gives an indication of the speed
range expected at the desired operating pressure range.

Use the

+

or keys to adjust this

value.

The console immediately determines

what the operating speed should be to
achieve the target application rate at this
pressure.

If the speed indicated is too high, a set

of smaller orifices or Micro-Tubes is
needed.

If the speed indicated is too low, a set of

larger orifices or Micro-Tubes is needed.

Press the

P

RO

key to advance to the speed calculation step.



Continue to try different speed, pressure and tip combinations. Once the correct
setting is determined:

Exit the Application Preset Mode by pressing and holding the

P

RO

key for 2

seconds.


Daily Flow Meter Maintenance

√ Remove flow meter from the system

√ Use a soft bristle brush to scrub the tube clean

√ Use clean water to wash any impurities out of the flow meter

√ Reinstall flow meter



2 0.0

GPA

12

6.0

0.019

MPH

PSI

Advertising