7. SYSTEM CONFIGURATIONS

7.1. Remote Microphone/VM Amplifier Configuration

(The Number of Connected Units)

Set the total number (0 – 5) of equipment (up to 1 sub-VM amplifier and up to 4 RM-200M Remote
Microphones) connected to the master VM amplifier using the master VM amplifier's internal DIP switches
SW3-No. 6, No. 7 and No. 8 "No. of connected units." Note that these switches in the sub-VM amplifier are not
used.

Set the Remote Microphone's Unit number (1 – 4) using DIP switches No. 1 and No. 2 on the microphone's
right side panel. The Unit number may be set regardless of the unit's connection order. (See p. 40 "VM
Amplifier's Internal Function Switches.")

7.2. Remote Microphone Operation Panel Function

The Zone/Message selector key function differs depending on the connected VM amplifier as described
below.

(1) 5 speaker zones with 1 VM amplifier

(2) 5 speaker zones with 1 VM amplifier (equipped with the EV-200M Board)

14

Message 1 – 5
selector key/indicator

Remote
microphone
RM-200M

VM amplifier

Zone 1 – 5
selector key/indicator

Voice announcement

board EV-200M

Remote

microphone

No. 2

Remote

microphone

No. 1

Remote

microphone

No. 3

Remote

microphone

No. 4

Master VM

amplifier

EV-200M

Sub-VM

amplifier

Sub-VM amplifier

(0 or 1 unit)

The number of Remote Microphones (0 – 4 units)

Voice
announcement
board (optional)

Remote
microphone
RM-200M

VM amplifier

Zone 1 – 5
selector key/indicator