22. SURVEILLANCE I/O CONNECTOR FUNCTIONS

The rear panel Surveillance I/O connector* permits "Speaker Line Reference Impedance Measurement (Initial
Setting)" and "Speaker Line Check" to be enabled and monitored by connected external equipment. Referring
to the pin arrangement and functions, prepare the matching D-sub male connector (screw-lock type) for
connection to the external equipment. (See p. 11 No. 41 SURVEILLANCE I/O connector.)

* Requires installation of the optional SV-200MA Surveillance Board.

SURVEILLANCE I/O connector pin function table

Function/status

Zone 1 speaker line is shorted.
Zone 1 speaker line is disconnected.
Zone 2 speaker line is shorted.
Zone 2 speaker line is disconnected.
Zone 3 speaker line is shorted.
Zone 3 speaker line is disconnected.
Zone 4 speaker line is shorted.
Zone 4 speaker line is disconnected.
Zone 5 speaker line is shorted.
Zone 5 speaker line is disconnected.
Some of speaker lines are grounded.
Power amplifier is faulty.
During measurement of the speaker line
reference impedance (Initial setting) or during
check of the speaker lines.
The speaker line reference impedance
couldn't be measured successfully.
(The measured impedance exceeds the
expected range or is unstable.)
Not connected

Check of the speaker line impedance starts.

Measurement of the speaker line reference
impedance (Initial setting) starts.

Pin

No.

1
2
3
4
5
6
7
8
9

10
11
12
13

14

15

I

22
23

24

25

Signal name

Zone 1 short
Zone 1 Disconnection
Zone 2 short
Zone 2 Disconnection
Zone 3 short
Zone 3 Disconnection
Zone 4 short
Zone 4 Disconnection
Zone 5 short
Zone 5 Disconnection
Ground fault
Power amplifier failure
Setting/checking busy

Initial setting error

Speaker line check
activation
Speaker line initial
setting activation
GND

IN

/OUT

OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT

OUT

IN

IN

Signal/logic

Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low

Active Low

One-shot make

One-shot make

SV-200MA's D-sub female connector

13

1

25

14

SURVEILLANCE I/O

Locking nut: 4-40 UNC

Advertising