38. Graphic equalizer output terminal

−20 dB*, 10 kΩ, unbalanced, RCA jack.

Connect this terminal to the graphic equalizer’s

input terminal.

39. Priority chime volume control

Adjusts the output volume of the chime tone that

sounds when the Priority Speech key on the

Chairman unit is pressed.

40. DC inlet

Connect the supplied AC adapter to this terminal.

41. Cable clip

Run the AC adapter cable through this clip to

prevent its plug from being removed from the DC

inlet.

42. Short circuit indicator

Lights when the Infrared Transmitter/Receiver

unit or its connected cable is shorted.

43. Infrared transmitter/receiver and Expansion

unit I/O terminals

Connect the Infrared Transmitter/Receiver unit,

Expansion unit, or Distributor to these terminals.
[Infrared Transmitter/Receiver connection]

By using the YW-1022 (2-branch distributor) and/

or YW-1024 (4-branch distributor), the following

maximum number of Infrared Transmitter/

Receiver units can be connected: 16 units when

they are all TS-905 units, 12 units when they are

all TS-907 units. (Also 12 units when both models

are mixed.)
[When connecting only the Expansion unit]

By using the YW-1022 (2-branch distributor) and/

or YW-1024 (4-branch distributor), up to 8 TS-918

Expansion units can be connected.

44. Functional earth terminal

Hum noise may be generated when external

equipment is connected to the unit. Connecting

this terminal to the functional earth terminal of the

external equipment may reduce the hum noise.

Note: This terminal is not for protective earth.

* 0 dB = 1 V