Infrared transmitter/receiver

Distributor

Central unit

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

M
M

M
M

N

When installing in the same space,
• All "L" cables must be identical in length

• All "M" cables must be identical in length.

Note

To facilitate the unification of coaxial cables used in

different connections into the same length, it is highly

recommended that wiring from the Central unit to the

distributor mounted in a ceiling be performed with

a single cable. For other ceiling wiring, using pre-cut

coaxial cables of a slightly longer length will facilitate

making all connections the same length.

(Example 2)

6.4.3. Wiring examples

(Example 1)

Infrared transmitter/receiver

Central unit

N
N

N
N

All cables for "N" must be identical in length when the Infrared

Transmitter/Receiver unit and the Central unit are installed in the

same space.

Infrared transmitter/receiver

Distributor

Central unit

L1

L1

L1

L1

L0

L0

L0

L0

L0

L0

L0

L0

M1

M0
M0

N

Conference room A

Conference room B

(Example 3)

When installing in multiple rooms where the light is

shut off, coaxial cables used in different rooms need

not be matched to the same length.
• All L0 cables are the same length.

• All L1 cables are the same length.

• All M0 cables are the same length.

• L0 and L1 cables need not be the same, since they

are used in different rooms.

• M0 and M1 cables need not be the same length,

since they are used in different rooms.

Note

The above condition also applies to cases in which two

conference systems, both including the Conference

units, are apart from each other in the same room so

that communications cannot be made between the two

systems.