Toa TS-910 Series Installation User Manual

Page 37

Advertising
background image

37

Attaching a YA-641 BNC Plug to the RG-6/U Cable

Step 1. Strip the jacket 10 mm from the end of the coaxial cable.

Step 2. Unravel the braided shield and turn it back, then peel away the

aluminum cladding.

Step 3. Strip the dielectric 4 mm from the cable end.

Step 4. Disassemble the BNC plug as shown in the figure at right and turn

the screw on the plug so that it loosens partially but remains in

position.

Step 5. Insert the coaxial cable into the clamping fixture.

Step 6. Insert the clamping fixture assembly into the plug.

Step 7. Tighten the screw and then clamp the plug by tightening the

clamping fixture.

Step 6. Insert the coaxial cable into the clamping fixture.

Step 7. Insert the clamping fixture assembly into the plug and then solder

the conductor.

Step 8. Insert the plug into the BNC connector.

Step 9. Clamp the connector by tightening the clamping fixture.

BNC connector

Clamping

fixture

BNC connector

Clamping fixture

Solder.

Conductor

(Finished)

10 mm

4 mm

Aluminum cladding

Braided shield

Conductor

Dielectric

Plug

Plug

Clamping

fixture

Screw

Plug

Screw

Clamping

fixture

Clamping fixture

(Finished)

10 mm

4 mm

Aluminum cladding

Braided shield

Conductor

Dielectric

Attaching a CC-4900 BNC Plug to the RG-6/U Cable

Step 1. Strip the jacket 10 mm from the end of the coaxial cable.

Step 2. Unravel the braided shield and turn it back, then peel away the

aluminum cladding.

Step 3. Strip the dielectric 4 mm from the cable end.

Advertising