Condition: Cable length between the Distributor and the TS-905 Infrared Transmitter/Receiver unit is assumed

to be 50 meters.

Central unit

Infrared Transmitter/Receiver units

TS-905

Distributor

L

L1

50 m

14.2.2. Example 2: When installing 4 TS-905 Infrared Transmitter/Receiver units using 1 coaxial cable

reaching from the Central unit (one 4-branch distributor connected):

1) Finding the maximum cable length using maximum allowable cable losses

Assuming that RG-59/U coaxial cable is used between the Distributor and the Infrared Transmitter/Receiver

unit, the cable loss between the two is calculated by the following equation:

Cable loss = 3.3 dB x (50 m / 100 m) = 1.65 dB

Since the Distributor's internal loss is 8.5 dB, the maximum allowable loss between the Central unit and the

Distributor becomes 9.85 dB (20 dB – 1.65 dB – 8.5 dB).

When RG-6/U coaxial cable is used between the Central unit and the Distributor, the length L1 between the

two is,
L1 = (Coaxial cable loss / its cable loss per 100 m )

= (9.85 dB / 2.7 dB) x 100 m

= 364 m

Maximum cable length L between the Central unit and the Infrared Transmitter/Receiver unit is calculated

by the following equation:

L = L1 + 50 m

= 364 m + 50 m

= 414 m

Similarly calculated for other types of coaxial cables, the maximum cable length between the Central unit

and the Infrared Transmitter/Receiver unit is found in the following table.

RG-59/U

348 m

RG-6/U

414 m

RG-11/U

542 m