9. FLUSH CEILING MOUNTING

• Use the optional C-BC511U or C-BC511U-S Flush Ceiling Mounting Bracket.
• Flush mounting can be used to reduce the camera's exposed area. Use the optional C-BC511U or C-

BC511U-S Flush Ceiling Mounting Bracket when mounting cameras to gypsum board ceilings or other weak
ceiling panel materials in which mounting screws cannot be securely inserted.

Notes
• Use the bracket whenever the space between suspended ceiling panel and upper ceiling exceeds a height

of 250 mm.

• The ceiling panel to which the camera will be mounted must be no more than 40 mm in thickness.
• Be sure to use the supplied safety wire.
• Be sure to use the specified screws to mount the combination camera and flush ceiling mounting bracket,

and ensure that they are securely mounted without any play.

Upper ceiling

250 mm or more

Ceiling panel

40 mm or less

9.1. Mounting Example

Safety wire
(supplied with the C-BC511U
and C-BC511U-S)

Anchor bolt for flush ceiling
mounting bracket

Upper ceiling

Anchor bolt for
safety wire

C-BC511U or C-BC511U-S
Flush Ceiling Mounting Bracket
(optional)

Ceiling panel

Combination camera