3

Load Cell Connections

The indicator can connect with a maximum of

eight (8) 350

Ω load cells, 4 wire or 6 wire

configurations.

Excitation voltage for the load cell is 5VDC, the

maximum output current is 120mA.

TS-700MS/WB Load Quick-Connect Pins





TS-700 SS Load Cell Terminal Block