Separator (ak) at the inlet, Notice, Notice separator (ak) at the inlet – VACUUBRAND MV 10C NT VARIO User Manual

Page 37

Advertising
background image

page 37 of 145

Use a suitable valve (see “Accessories / Spare

parts”, pg. 92) to isolate the pump from the

vacuum application. This is to allow the pump

to warm up before pumping condensable va-

pors and to clean the pump after use before it

is switched off.

NOTICE

+

Particles and dust must not be aspirated. If necessary,

you must install appropriate filters. You must ensure

their suitability concerning gas flow, chemical resis-

tance and resistance to clogging prior to use.

• A power failure may cause accidental ventilation of the

pump, especially if the gas ballast valve is open. If this

constitutes a potential source of danger, take appropri-

ate safety measures.

When assembling, ensure

vacuum-tightness. After as-

sembly, check the whole system for leaks.

NOTICE

Separator (AK) at the inlet

The separator at the inlet protects against

droplets and particles from entering the pump.
+

Enhances lifetimes of diaphragms and

valves.

+

Improves vacuum performance in applica-

tions with condensable vapors.

Assemble the separator (AK) with clamping

ring and centring ring KF DN 25.

Catchpot:

The catchpot is coated with a protective layer

to protect against shattering in case of break-

age or implosion.

Assemble the catchpot at the inlet using a

joint clip.

Advertising