Campbell Hausfeld Serial I/O Interface SDM-SIO4 User Manual

Page 42

Advertising
background image

SDM-SIO4 User Guide

5-12

5.2.20 Command 2054: Set Up Receive Filter

This command clears all buffers relevant to the mode number and restarts the
filter.

Values per repetition = 0

With the string filter type the SDM-SIO4 buffers are not cleared.

First Command Option (Parameter 5)

Input mode
| String number or character code
| | | |
x x x x

Input Mode:
0

No filter

1

Convert any ASCII numbers to Campbell Scientific floating point up to the
termination character if set

2

Convert any ASCII hex pair to Campbell Scientific floating point up to the
termination character if set

3

Convert 8-bit binary number to Campbell Scientific floating point up to the
termination character if set

4

Convert 16-bit binary number to Campbell Scientific floating point up to the
termination character if set.

8

Transmit a user-defined string 0-255 or fixed string 256-511

9

String filter type. See Filter Strings in Section 2.3.

String Number or Character Code:

If input mode 9 is chosen, this is the user-defined filter string number 0..255 or
fixed filter string 256..511 used for the filter; if the string is not allocated the filter
will not operate. If input mode 8 is chosen, this number is the defined string 0-255
or fixed string 256-511. If input modes 1 to 4 are chosen, this is the termination
character as an ASCII code 0..255; 999 means character not enabled.

Minimum delay = 4 +(characters to Tx)*0.26*ports, in milliseconds.

5.2.21 Command 2304: Transmit String and/or Data to Device

(Formatter/Filter)

This command transmits a string and/or floating point data and optionally sets up
a filter ready for returned data.

Values per repetition = 0

First Command Option (Parameter 5)

Output mode
| String number or termination character
| | | |
x x x x