SECTION 5

SERVICE TECH. INFORMATION

5A.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate computer has a self-diagnostic
function for the electrical system (except input

power and water meter). The computer monitors the
electronic components and circuits
for correct operation. If a malfunc­

tion occurs, an error code appears
in the face plate display.

СГГ

The chart below shows the error codes that could
appear, and the possible defects for each code.

While an error code appears in the display, all face
plate buttons are inoperable except the SELECT
button. The SELECT button remains operational so
the service person can make the Manual Initiated
Electronic Diagnostics to further isolate the defect,
and check the water meter.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Err 01

motor inoperative / wiring harness or connection to switch / position switch / face plate

Err 02

face plate

Err 03

motor inoperative / face plate

Err 04

face plate / position switch

Err 05

face plate

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE:

1 Unplug transformer 2 Correct defect 3 Plug in

transfctrmer 4. Wait for 6 minutes. The errctr cctde will return if the defect was nett cctrrected.

MANUAL

INITIATED

ELECTRONIC

DIAG­

NOSTICS

1.

To enter diagnostics, press and hold the SELECT

button until

000

— shows in the display.

TURBINE SWITCHES

nnn_______

1Л1Л1-! ^

О

WATER METER

(A)

SWITCH

(B)

A. The first 3 digits indicate water meter operation

as follows:

000 (steady) = Soft water not in use, and no
flow through the meter.

— OPEN A NEARBY SOFT WATER FAUCET —

000 to 199 (continual) = Repeats display for
each gallon of water passing through the meter.

If you don’t get a reading in the display, with the
faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front of
the sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.

MOTOR

POSITION

SWITCH

SENSOR

HOUSING

TURBINE

TURBINE

SUPPORT AND

SHAFT

B.

VALVE

OUTLET

The letter (P) and dash (or dashes) indicate POSI­
TION switch operation. If the letter appears, the
switch is closed. If the dash shows, the switch is
open.

Use the ON/OFF-HOLD (Recharge Now) button
to manually advance the valve into each cycle
and check correct switch operation.