Installation

Packing Material

Remove protective packing materials from range. Tape
residue can be cleaned with a soft cloth and alcohol.

Range Location

Underwriter’s Laboratories, Inc, specifies range can be
installed flush against right and left base cabinets, and
rear vertical wall. Range can also be installed flush

against left or right vertical wall extending above 36 inch
standard countertop height.

Cabinet Opening

^ WARNING

To avoid risk of burns or fire by reaching over elements,
cabinet storage space located above range should be
avoided. If cabinet storage is provided, install a range
hood that projects horizontally a minimum of 5 inches
beyond the cabinet bottom to reduce the risk.

À CAUTION

Do not store items of interest to children in cabinets

above a range or behind the backguard of a range.
Children climbing on the range to reach items could
be seriously injured.

Range should extend approximately 2 inches from

cabinet front to oven door handle. Using dimensions,
prepare cabinet opening.

A—30'/8 to 30V4 inches
B—36 inches standard
C—35 inches standard
D—23 inches standard
E—25 inches standard

Minimum Clearances to Combustible
Surfaces

Using dimensions, prepare cabinet opening.
• Minimum clearance to rear wall is 0 inches,
• Minimum clearance to a vertical right or left side wall is

0 inches.

• Minimum clearance to countertop/cabinet on each side

is 0 inches,

• Minimum of 30 inches between top of cooking surface

and bottom of an unprotected wood or metal cabinet.

• Minimum of 24 inches between cooking surface and

protected wood or metal cabinet above range. Cabinet
bottom must be protected by at least % inch thick
millboard with not less than No. 28 MSG sheet steel,
.015 inch thick stainless steel, .024 inch thick
aluminum, or .020 inch thick copper.

A—30 inches minimum
B—30 inches unprotected: 24 inches protected minimum
C—13 inches maximum
D—25 inches maximum
E—36 inches maximum

Minimum Clearances to Combustible Surfaces