Range has been grounded at the factory to the center
(nickel plated) terminal of the terminal block in

accordance with the National Electrical Code (section
2560). When a separate ground is required by local code,
disconnect the grounding strap from the terminal block.
Ground frame by connecting a grounding wire to range
frame using only the grounding screw removed from the
grounding strap.

Neutral terminal connect wire

with white insulation

with black or red insulation
and brass terminal

Installing 3-Wire Power Cord

Refer to power cord instructions if available for additional
information.
1.

Remove rear wire cover on rear of range.

2. Place strain relief (winged clamp) in cord access hole

below terminal block.
• Strain relief is supplied with cord. Place wings

through hole, entering from bottom. Screw holes in

clamp should be below mounting panel. Place cord

through strain relief,

3. Attach neutral (center) or white wire to center terminal

on terminal block.

4. Attach power lead, red wire or black wire to left side

power terminal.

5. Attach power lead, red wire or black wire to the right

side power terminal.

6.

After wires have been placed on terminals, attach

with hex nuts provided.

• Firmly tighten to ensure proper electrical

connection.

7.

Place screw through strain relief and tighten,

8.

Replace rear wire cover.

Wires from range

(Number of wires on each terminal can vary)

Terminal Block

Terminal block is approved for copper wire connection
only, NOT aluminum wiring. If aluminum house wiring
is to be connected, the following procedure is suggested,

1.

Connect length of copper building wire to range

terminal block with ring terminals.

2. Splice copper wires to aluminum wiring using

connectors which are designed certified by

Underwriter’s Laboratories and recognized for joining

copper to aluminum. Follow the connector
manufacturer’s recommended procedure.

3. Wire used, location and enclosure of splices must

conform to local codes.

A—Power lead temiinal (Connect black or red insulated wire and

secure with brass nut.)

B—^Neutral terminal (Connect insulated white insulated wire and

secure with brass nut.)

Installing 3-wire Power Cord