Irregular Cabinet and Countertop Heights

Countertops such as ceramic tile tops cause cabinet and
countertopto behigherthan 36 inches. Follow instructions
below when countertop is higher than 36 inches.

1. Raise leveling legs to maximum height.

2. Measure from floor to rangetop. If measurement is

less than height of countertop, floor must be
shimmed.

3. Shim floor using a piece of plywood same size as

range opening. Secure plywood to floor. Plywood
must be as secure as original flooring.

4. Install anti-tip bracket and slide range into place.

Power Cord Requirements

Power cord is not supplied with range. Power cord must

be U.L, Listed and meet NEC and Mobile Home

Manufacturers Association Standards. Cord must be

rated at a minimum 250V—40 AMP, equipped with a
plug configuration in accordance with NEMA, Conductors
must end with closed loop (ring) terminals at the range.
• Three-conductor cord plug NEMA 10-50P allowed for

residential,

• Four-conductor cord plug NEMA 14-50P required for

most mobile home installations but can be used for
residential.

Line Voltage Requirements

Line voltage must not exceed rated voltage. See rating plate

attached to range for kilowatt rating. Line voltage less than
rated voltage will result in slow heating. Wiring system must
conform to Underwriters Laboratories, Inc. standards and

National Electrical Code, Installation must conform to all

local, municipal and state building codes, and local utility
regulations. Range must be connected only to a supply
circuit as specified on rating plate wiring diagram of range.

Range requires 3 wires, 120/240 Volts, 60 Hertz A.C.
House wiring and fusing must comply with local wiring

codes. If no codes apply, wire according to National

Electrical Codes.

Power Supply Location

Shaded area show range clearance for electrical
connection.

NOTE; Only a power cord suitable for use with ranges may

be used. For installation in a mobile home, or area where
local codes do not permit grounding through the neutral
terminal, a 4-wire cord must be used.

Range Terminal Block

Connection block is located at bottom rear of range
behind rear cover panel. Remove rear cover screw.

Directly below terminal block is a hole for a power supply

service cord. Power cord is not supplied with range.

Attach Power Cord

A—3 inches
B—7 inches
C—6 inches
D—30‘/8 inches minimum
^247i6

Power Supply Location

Advertising