GENERAL INSTALLATION INFORMATION

PURPOSE AND SCOPE OF MANUAL

These Installation Instructions have been prepared
especially for the purpose of familiarizing installers
and owners of the applicable equipment with the pro­
duct's installation requirements. Give serious consid­
eration to all information and instructions in the
Manual, both for safety and for continued reliable
operation of the equipment.

Because of the different recreational vehicle models

and the variations between the models, it would be
extremely

difficult,

if

not

impractical,

to

provide

detailed instructions on every installation possibility.
For that reason, instructions and illustrations in this
manual are general in nature. Illustrations are not
intended to serve as detailed installation blueprints.

The installation should comply strictly with all applica­

ble codes, standards and regulations pertaining to the
installation and use of this product. If any portion of

this manual appears to be in conflict with such codes,
standards or regulations, the applicable codes, stan­
dards or regulations must take precedence over the

manual.

SAFETY

Before handling, installing, operating or servicing this
equipment, be sure to read carefully the “Notice to

Installer” and “Safety Rules” at front of this manual.

Comply with all SAFETY RULES to prevent death,
personal injury or damage to equipment and/or prop­
erty. Stress safety to all installers, operators and ser­
vice technicians who work on this equipment.

STANOAROS BOOKLETS

Installation, use and servicing of this equipment

should comply strictly with published standards, as
well as the manufacturer's recommendations. The fol­
lowing standards booklets (latest revision) are avail­

able from the sources indicated:

1.

NFPA Standard 501C, “Standard for Recreational

Vehicles”, available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269.

2.

NFPA 70, “NFPA Handbook of the National Electric

Code”, obtained from same address as Item 1.

3. ANSI CM975 and ANSI 119.2-1975, available from the

American National Standards Institute, 1430 Broadway,

New York, NY 10018.

4.

ANSI

A119.2/NFPA

501C,

available

from

the

Recreational Vehicle Association, 1896 Preston White
Drive, Reston, VA 22090.

5. California Administrative Code, Title 25, available from

the State of California, Documents Section, P.O. Box

1015, North Highlands, CA 95660.

6. CSA Electrical Bulletin 946, available from the Canadian

Standards

Association,

Housing

and

Constructions

Materials Section, 178 Rexdale Boulevard, Rexdale,
Ontario, Canada, M9W 1R3,

EQUIPMENT DESCRIPTION

Instructions and information in this section pertain to
Generac air-cooled generators — more specifically,

the installation of NP30 recreational vehicle genera­
tors. These generators are designed specifically for

installing in recreational vehicles.

ENGINE GENERATOR

OPERATING SPEED

The generators are driven by single-cylinder engines.
The engines drive revolving fields (rotors), high fre­
quency, permanent magnet alternators. The genera­
tors supply 120 volts AC at 60 Hertz. The generators

revolving fields are driven at a variable speed

depending on the instantaneous demand for power.
Computers

monitor

that

demand

and

adjust

the

engine speed to provide adequate power to the con­
nected loads.

GENERATOR AC CONNECTION

SYSTEM

The generators are equipped with single voltage AC
connection systems. The following facts pertain to
such a connection system:

• On the units, the 120 volts, connections system is pro­

tected by a circuit breaker.

• The AC connection system on all air-cooled generators

use a GROUNDED neutral.

• A separate green ground wire is connected to the recre­

ational vehicle's junction box.

_ 1 4 _ _