Electrical Specifications

1 All wiring must comply with local and national

electrical codes and must be installed by a

qualified electrician If you have any questions

regarding the following instructions, contact a

qualified electrician

2 Check available power supply and resolve any

wiring problems

BEFORE installing and operating

this unit

3 This 115V air conditioner uses 12 0 or less

nameplate amps and may be used in any

properly wired, general purpose household

receptacle See (Table 1) for specifications for

individual branch circuit

4 For your safety and protection This unit is

grounded through the power cord when

plugged into a matching wall outlet

If you are

not sure weather your wait outlet is properly

grounded, please consult a qualified

electrician

5 The wall outlet(3-pin) must match the plug

(3-pin) on the service cord supplied with the unit

DO NOT use plug adapters See (Table 2) for

receptacle and fuse infomnatton

6 The rating plate on the unit contains electrical

and other technical data. The rating plate is located

on the right side of the unit, above the power cord

If missing, a second nameplate is located on front

chassis (also as known as basepan)

Suggested Individual Branch Circuit

Hameplate Amps

5 Oto 12

AWG Wire Size*

14

AWG- American Wire Gage

* Based on copper wire at 60° C temperature rating

Table 1

Receptacle and Fuse Types

Rated Volts

125

AMPS

15

Walt Outlet

(

5

)

Fuse Size

15

Time Delay Fuse

(or circuit breaker)

Pfug type

Table 2

Electric Shock Hazard

To avoid the possibility of personal

injury, disconnect power to the unit
before installing or servicing