Instal latîon Instructions

CAUTION

A

Because the compressor is located on the

controls side of the unit (right side), this side

will be heavier and more awkward to manipulate

Inadequate support on control side of the unit

can result in personal injury and damage to your
unit and property Therefore, it is recommended

to have someone assist you during the installation
of this unit

F Your Bryant unit was designed to evaporate

condensation under normal conditions However,

under extreme humidity conditions, excess condensation

may cause basepan to overflow to the outside

The unit should be installed where condensation

run-off cannot drip on pedestrians or neighboring

properties

G A drain connection{exciuding hose) is provided

If you need to redirect condensation overflow

(See Fig 23 on Page 12)

1. Select the Best Location

A Your Bryant room air conditioner was designed to

fit easily into a single or double hung window However,

since window designs vary, it may be necessary to

make some modifications for safe and proper

installation

B Make sure window and frame is structurally

sound and free from dry and rotted wood

C For maximum efficiency, install the air conditioner

on side of the house or building which favors more

shade than sunlight If the unit Is in direct sunlight,

it is advisable to provide an awning over the unit

D Provide sufficient clearance around the cabinet

to allow for ample air circulation through the unit

See (Dwg 1) The rear of the unit should be outdoors

and not in a garage nor inside of a building

Keep unit as far away as possible from obstacles

obstructions and at least 30" above the floor or ground

Curtains and other objects within a room should be

prevented from blocking the air flow

E Be certain the proper electrical outlet is within reach

of the installation Use only a single outlet circuit rated

at 15 amps All wiring should be in accordance with local

and national electrical codes

Awning

Fence,

wail, or

other

obstacle

Ground

Dwg 1