Compaq 4000N User Manual

Page 108

Advertising
background image

Chapter 5 Input/Output Interfaces

Compaq Deskpro 4000N and 4000S Personal Computers

First Edition – September 1997

5-18

Baud Rate Divisor Latch Register, I/O Port 3F8h, 3F9h/2F8, 2F9h

When bit <7> of the Line Control register is set (1), a write to this pair of locations loads the
decimal value used to divide the 1.8462-MHz clock to create the desired baud rate for serial
transmission. The possible baud rates are shown as follows:

Baud Rate

Decimal Divisor

Baud Rate

Decimal Divisor

50

2304

2400

48

75

1536

3600

32

110

1047

4800

24

134.5

857

7200

16

150

768

9600

12

300

384

19200

6

600

192

38400

3

1200

96

57600

2

1800

64

115200

1

2000

58

Divisor = 1846200 / (Desired baud rate X 16)

Interrupt Enable Register, I/O Port 3F9h/2F9h

Bits <3..0> of this register are used for enabling interrupt sources. A set bit enables interrupt
generation by the associated source.

Bit

Function

7..4

Reserved

3

Modem Status Interrupt Enable (if set) (CTS, DSR, RI, CD)

2

Receiver Line Status Interrupt Enable (if set) (Overrun error,
parity error, framing error, break)

1

Transmitter Holding Register Empty Interrupt Enable (if set)

0

Baud Rate Divisor Interrupt Enable (if set)

Interrupt ID Register, I/O Port 3FAh/2FAh (Read Only)

This read-only register indicates the serial controller as the source of the interrupt (bit <0>) as
well as the reason (bits <3..1>) for the interrupt. Reading this register clears the interrupt and
sets bit <0>.

Bit

Function

7,6

FIFO Enable/Disable
0 = Disabled
1 = Enabled

5,4

Reserved

3..1

Interrupt Source:
000 = Modem status (lowest priority)
001 = Transmitter holding reg. Empty
010 = Received data available
011 = Receiver line status reg.
100,101 = Reserved
110 = Character time-out (highest priority)
111 = Reserved

0

Interrupt Pending (if cleared)

Advertising