A.13 hard drive error messages (17xx-xx) – Compaq 4000N User Manual

Page 168

Advertising
background image

Appendix A Error Messages and Codes

Compaq Personal Computers

Changed - September 1997

A-8

A.13

HARD DRIVE ERROR MESSAGES (17xx-xx)

Table A–12. Hard Drive Error Messages

Table A-12.

Hard Drive Error Messages

Message

Probable Cause

Message

Probable Cause

17xx-01

Exceeded max. soft error limit

17xx-51

Failed I/O read test

17xx-02

Exceeded max. Hard error limit

17xx-52

Failed file I/O compare test

17xx-03

Previously exceeded max. soft error limit

17xx-53

Failed drive/head register test

17xx-04

Previously exceeded max.hard error limit

17xx-54

Failed digital input register test

17xx-05

Failed to reset controller

17xx-55

Cylinder 1 error

17xx-06

Fatal error while reading

17xx-56

Failed controller RAM diagnostics

17xx-07

Fatal error while writing

17xx-57

Failed controller-to-drive diagnostics

17xx-08

Failed compare of R/W buffers

17xx-58

Failed to write sector buffer

17xx-09

Failed to format a track

17xx-59

Failed to read sector buffer

17xx-10

Failed diskette sector wrap during read

17xx-60

Failed uncorrectable ECC error

17xx-19

Cntlr. failed to deallocate bad sectors

17xx-62

Failed correctable ECC error

17xx-40

Cylinder 0 error

17xx-63

Failed soft error rate

17xx-41

Drive not ready

17xx-65

Exceeded max. bad sectors per track

17xx-42

Failed to recalibrate drive

17xx-66

Failed to initialize drive parameter

17xx-43

Failed to format a bad track

17xx-67

Failed to write long

17xx-44

Failed controller diagnostics

17xx-68

Failed to read long

17xx-45

Failed to get drive parameters from ROM

17xx-69

Failed to read drive size

17xx-46

Invalid drive parameters from ROM

17xx-70

Failed translate mode

17xx-47

Failed to park heads

17xx-71

Failed non-translate mode

17xx-48

Failed to move hard drive table to RAM

17xx-72

Bad track limit exceeded

17xx-49

Failed to read media in file write test

17xx-73

Previously exceeded bad track limit

17xx-50

Failed I/O write test

--

--

1700-xx = Hard drive ID test

1710-xx = Hard drive park head test

1701-xx = Hard drive format test

1714-xx = Hard drive file write test

1702-xx = Hard drive read test

1715-xx = Hard drive head select test

1703-xx = Hard drive read/write compare test

1716-xx = Hard drive conditional format test

1704-xx = Hard drive random seek test

1717-xx = Hard drive ECC test

1705-xx = Hard drive controller test

1719-xx = Hard drive power mode test

1706-xx = Hard drive ready test

1721-xx = SCSI hard drive imminent failure

1707-xx = Hard drive recalibrate test

1724-xx = Net work preparation test

1708-xx = Hard drive format bad track test

1736-xx = Drive monitoring test

1709-xx = Hard drive reset controller test

1799-xx = Invalid hard drive type

Advertising