25

SSI Connector (J3)

Legend:

SSI_TIMEBASE

1

2

DGND

SSI_ADCONV

3

4

DGND

SSI_DAWR 5

6

DGND

SSI_SCAN_START

7

8

DGND

RESERVED

9

10

DGND

SSI_AD_TRIG

11 12

DGND

SSI_DA_TRIG

13 14

DGND

RESERVED

15 16

DGND

RESERVED

17 18

DGND

RESERVED

19 20

DGND

Table 3-3: SSI Connector (JP3) Pin Assignment for DAQ Models

SSI timing signal

Functionality

SSI_TIMEBASE

SSI master: send the TIMEBASE out

SSI slave: accept the SSI_TIMEBASE to

replace the internal TIMEBASE signal.

SSI_ADCONV

SSI master: send the ADCONV out

SSI slave: accept the SSI_ADCONV to

replace the internal ADCONV signal.

SSI_SCAN_START

SSI master: send the SCAN_START out

SSI slave: accept the SSI_SCAN_START to

replace the internal SCAN_START signal.

SSI_AD_TRIG

SSI master: send the internal AD_TRIG out
SSI slave: accept the SSI_AD_TRIG as the

digital trigger signal.

SSI_DAWR

SSI master: send the DAWR out.

SSI slave: accept the SSI_DAWR to replace

the internal DAWR signal.

SSI_DA_TRIG

SSI master: send the DA_TRIG out.

SSI slave: accept the SSI_DA_TRIG as the

digital trigger signal.

Table 3-4: SSI Connector Legend