Software update, Table 4-6: unipolar output code table – ADLINK DAQe-2006 User Manual

Page 60

Advertising
background image

48

Operation Theory

The D/A conversion is initiated by a trigger source. You must
decide how to trigger the D/A conversion. The data output will start
when a trigger condition is met. Before the start of D/A conversion,
D/A data is transferred from the computer’s main memory to a
buffering Data FIFO.

There are two modes of the D/A conversion: Software Update and
Timed Waveform Generation. These are described below, includ-
ing the timing, trigger source control, trigger modes, and data
transfer methods. Either mode may be applied to D/A channels
independently. You can software update DA CH0 while generating
timed waveforms on CH1 at the same time.

Software Update

This is the easiest way to generate D/A output. To do this:

1. Specify the D/A output channels.

2. Set output polarity (unipolar or bipolar) and reference

source (internal 10V or external AOEXTREF).

3. Update the digital values into D/A data registers through

a software output command.

Digital Code

Analog Output

111111111111 Vref * (4095/4096)

100000000000 Vref * (2048/4096)

000000000001

Vref * (1/4096)

000000000000

0V

Table 4-6: Unipolar Output Code Table

Advertising
This manual is related to the following products: