Operation Theory

47

4.2

D/A Conversion

There are two 12-bit D/A output channels available in the DAQ-/
DAQe-/PXI-2016/2010/2006/2005 card. When using D/A convert-
ers, you should assign and control the D/A converter reference
sources for the D/A operation mode and D/A channels. You could
also set the output polarity to unipolar or bipolar.

The reference selection control lets you utilize in full the multiply-
ing characteristics of the D/A converters. Internal 10V reference
and external reference inputs are available in the DAQ-/DAQe-/
PXI-2016/2010/2006/2005 card. The range of the D/A output is
directly related to the reference. The digital codes that are updated
to the D/A converters will multiply with the reference to generate
the analog output. While using internal 10V reference, the full
range would be –10V to +9.9951V in the bipolar output mode, and
0V to 9.9976V in the unipolar output mode. While using an exter-
nal reference, you can reach different output ranges by connecting
different references. For example, if connecting a DC –5V with the
external reference, then you can get a full range from –4.9976V to
+5V in the bipolar output with inverting characteristics due to the
negative reference voltage. You could also have an amplitude
modulated (AM) output by feeding a sinusoidal signal into the ref-
erence input. The range of the external reference should be within
±10V. Table 4-5 and 4-6 illustrates the relationship between digital
code and output voltages

with Vref=10V and if internal reference is

selected

.

Digital Code

Analog Output

111111111111 Vref * (2047/2048)

100000000001

Vref * (1/2048)

100000000000

0V

011111111111

-Vref * (1/2048)

000000000000

-Vref

Table 4-5: Bipolar Output Code Table