Power and ground – ADLINK Express-BE User Manual

Page 25

Advertising
background image

Express-BE

Page 25

Signal

Pin # Description

I/O

PU/PD

Comment

LID#

A103 LID button. Low active signal used by the ACPI operating system for a LID

switch.

I OD
3.3VSB

PU 10k
3.3VSB

Emulated on
GPIO (BIOS)

SLEEP#

B103 Sleep button. Low active signal used by the ACPI operating system to bring

the system to sleep state or to wake it up again.

I OD
3.3VSB

PU 10K
3.3VSB

Emulated on
GPIO (BIOS)

3.3.18. Power and Ground

Signal

Pin #

Description

I/O PU/PD

Comment

VCC_12V A104-A109

B104-B109

Primary power input: +12V nominal (wide range 5 ~ 20V).

All available VCC_12V pins on the connector(s) shall be used.

P

8.5~20

V

VCC_5V_SBY B84-B87

Standby power input: +5.0V nominal. See section 7 “Electrical
Specifications“ for allowable input range. If VCC5_SBY is used,
all available VCC_5V_SBY pins on the connector(s) shall be
used. Only used for standby and suspend functions. May be left
unconnected if these functions are not used in the system design.

P

5Vsb

±5%

VCC_RTC

A47

Real-time clock circuit-power input. Nominally +3.0V.

P

GND

A1, A11, A21, A31, A41, A51,
A57, A66, A80, A90, A96, A100,
A110, B1, B11, B21 ,B31, B41,
B51, B60, B70, B80, B90, B100,
B110

Ground - DC power and signal and AC signal return path.

P

Advertising